Product
Recommended article
- Integrated meteorological monitoring station High-Efficiency Monitoring for Multi-Domain Applications
- Radar speed gun with Printing Function for Mobile Speed Enforcement
- compact weather station Multi-Element Monitoring and Multi-Domain Applications
- Photovoltaic module efficiency testing equipment Provides High-Voltage, High-Power Performance Testing Solutions
- Forest Fire Detection Provides Automatic Meteorological Monitoring and Forest Fire Warning
- I-V Curve Tracer: Outdoor Measurement Equipment for Photovoltaic Module Current-Voltage Characteristic Testing
Contact us
Shandong Fengtu IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

Electrical Power Analyzer
Model:FT-DN2
Brand:fengtu
Related products
1.Functional features of Electrical Power Analyzer
Electrical Power Analyzer is used to understand the actual power quality of the power grid, and master the power quality and load of the measured point.
1.Multi-channel measurement: 4 voltage channels and 4 current channels are measured simultaneously.
2.Electrical parameter measurement: The voltage amplitude, current amplitude, phase, frequency, active power, reactive power, power factor and other numbers can be measured simultaneously;
3.The voltage harmonic and current harmonic content can be measured 2-64 times;
4.The total harmonic distortion rate can be measured;
5.It can measure and short-term flicker (PST), long-term flicker (PLT), and voltage fluctuations;
6.It can measure positive sequence voltage, negative sequence voltage, zero sequence voltage, and voltage imbalance;
7.It can measure positive sequence current, negative sequence current, zero sequence current, current imbalance;
8.Transient parameter measurement function, with voltage surge and drop event recording function, and automatically starts the wave recording function to record the time of the occurrence of the event and the actual waveform of the five cycles before and after;
9.It has oscilloscope function, which can display the voltage and current magnitude and distortion in real time, and can display the voltage and current waveform on the instrument;
10.The hexagonal diagram display function can perform vector analysis of the metering circuit and the protection device circuit, and conduct wrong wiring checks of the metering device; in the three-phase and three-wire wiring mode, 48 wiring methods can be automatically judged; the automatic calculation function of the power supply is convenient for users who have problems with wiring to calculate the power supply.
11.The large clamp meter can be used to measure the ratio and angle difference of low-voltage current transformers;
12.Harmonic content can be displayed in the form of a bar chart, with good visual effect;
13.Built-in large-capacity data memory (storage interval is 1 second-1000 minutes optional) can be continuously stored for 18 months at a time interval of 1 minute;
14.10-inch large-screen color LCD screen display 1280×800;
15.The touch operation of the capacitive screen is similar to that of the operation of tablets and smartphones, making it easy to learn;
16.Support mouse operation and adapt to operators with different habits;
17.When measuring harmonics, you can automatically determine whether the harmonic content exceeds the standard according to the national standard and give a prompt, which is clear at a glance;
18.The national standard query function of harmonic content ratio can query the allowed values of the national standard;
19.It has a frequency measurement range of 42.5Hz-69Hz, and can measure 50 and 60 power systems.
20.Data can be stored in USB flash drive for historical query.
21.It can be equipped with special data analysis and management software to analyze and process the test results, and can grasp the periodic changes of the power quality and load of the measured points, and play an irreplaceable role in understanding the user's power quality and taking corresponding treatment measures;
22.The analysis software can generate professional power quality analysis reports in accordance with the national standard requirements;
23.The instrument is small in size, light in weight and easy to carry;
24.Built-in high-performance lithium-ion battery, which automatically enters power-saving mode, allows the instrument to work continuously for more than 10 hours without an external power supply, making it convenient for on-site testing;
2.Electrical Power Analyzer Technical Indicators
| project | parameter | |
| Measure the number of channels | Four-channel voltage, four-channel current | |
| Measurement range | Voltage | 0-900V |
| Current | Small clamp watch: diameter 8mm, 0-5A-25A (standard) Medium clamp watch: diameter 50mm, 10-100-500A (optional) Large clamp watch: diameter 125×50mm, 40-400-2000A (optional) | |
| Phase angle | 0.000-359.999° | |
| frequency | 42.5-69Hz | |
| Resolution | Voltage | 0.001V |
| Current | 0.0001A | |
| Phase angle | 0.001° | |
| power | Reactive 0.01W, reactive 0.01Var | |
| frequency | 0.0001Hz | |
| Voltage RMS Accuracy | ≤0.1% | |
| Current RMS deviation | ≤0.3% | |
| Phase angle error | ≤0.1° | |
| Power deviation | ≤0.5% | |
| Frequency measurement accuracy | ≤0.01Hz | |
| Number of harmonic measurements | 2-64 times | |
| Voltage harmonic deviation | When the harmonic is greater than 1% nominal value: ≤1% Reading Harmonic is less than 1% nominal value: ≤0.05% nominal voltage value | |
| Current harmonic deviation | When the harmonic is greater than 3% nominal value: ≤1% reading + CT accuracy when the harmonic is less than 3% nominal value: ≤0.05% current range | |
| Voltage imbalance accuracy | ≤0.2% | |
| Current imbalance accuracy | ≤0.5% | |
| Short flicker measurement time | 10 minutes | |
| Long flicker measurement time | 2 hours | |
| Flash measurement deviation | ≤5% | |
| Display | 1280×800, color wide temperature LCD screen | |
| Charging power supply | AC220V±15% frequency 45Hz-65Hz | |
| Battery working hours | ≥8 hours | |
| Power consumption | <4VA | |
| insulation | The insulation resistance of the voltage and current input terminals to the casing is ≥100MΩ.The working power input end bears a power frequency of 1.5KV (valid value) between the housing, which took 1 minute to experiment. | |
| Ambient temperature | -20℃~50℃ | |
| Relative humidity | 0-95% No condensation | |
| Appearance size | 280mm×210mm×58mm (Length×Width×Height) | |
| weight | 2Kg | |
Related article
-
Fengtu's Photovoltaic Weather Station: Enabling Precise Meteorological Monitoring for Photovoltaics
2025-08-06 -
Fengtu's Negative Oxygen Ion Monitoring Systems: Empowering Environmental Monitoring and Decision-Making
2024-10-23 -
Intelligent agro-meteorological monitoring stations
2024-07-04 -
Road weather stations to monitor road weather
2024-04-03 -
Integrated meteorological monitoring station High-Efficiency Monitoring for Multi-Domain Applications
2026-01-28 -
Fighting Against Dust: The Role of Dust Detector in Urban Sustainability
2024-12-18 -
Vehicle - Mount Weather Stations: Applications and Advantages
2024-11-11 -
All-Weather Dust Monitoring Equipment: Functions, Advantages and Applications
2025-08-12


Get a Free Quote